Air ring blower:
Air ring fan, also known as side flow fan or air ring vacuum pump, is used for exhaust.
Working principle of G series gas ring pump:
The G series impeller is directly installed on the motor rotor and undergoes complete non-contact compression. Due to the installation of the pump shaft outside the compression chamber, the reliability of the machine's Z-large operation can be ensured even when working under Z-large pressure differentials.
The gas is sucked in through the suction port 1, and when it enters the side channel 2, the rotating impeller 3 gives the gas a velocity in the direction of rotation. At the same time, the centrifugal force on the blades accelerates the gas outward and increases the pressure. As the rotation progresses, the kinetic energy of the gas increases, causing the gas pressure along the side channel to further increase. As the side channel narrows at the outlet, gas is squeezed out of the blades and discharged from the pump body through the outlet muffler 4.